AeroDR New Standard 14×17 inch flat panel detector

A KonicaMinolta launched New Standard Panel the "AeroDR 2 1417S"(14×17-inch) by redesigning the current standard model(AeroDR 1417S) and ading the AeroSync function for added convenience.

Wireless Digital radiography System AeroDR 2 1417S

Product name (model name) AeroDR P-52 (AeroDR 2 1417S)
Detection method Indirect conversion method
Scintillator CsI (Cesium Iodide)
External dimensions (W×D×H) 383.7×460.2×15.9mm (15.0×17.9×0.6 inch)
Weight 2.5kg (5.5lb)
Pixel size 175μm
Image area size 348.95×425.25mm (13.6×16.6 inch) (1,994×2430 pixcels) 
AD conversion 16 bit(65,536 gradients)
Usable grid frequency 40lp/cm, 34lp/cm
Durability ※1 Point load: 150kg@φ40mm
Face load: 300kg@ effective image area overall
Water resistance ※2 IPX6
Communication Dedicated wired ethernet connection/ Wireless LAN (IEEE802.11a/IEEE802.11n compliant)
W-LAN encryption Wireless encryption method: AES/ Authentification method: WPA2-PSK
Cycle time ※3 Approx. 4 seconds with dedicated wired connection
Approx. 6 seconds with wireless LAN connection
Operating time ※3, 4 150 images/ 4.1 hours
Battery charging time empty to full Within 13 minutes
(When using the AeroDR Battery Charger2, AeroDR Interface Cable2)
Battery duration in standby status
※5
10 hours
Battery expected life time Same as the AeroDR panel life time
Recommended storage and usage environment condition When operating:
(Temperature) 10 to 30℃ (30 to 86℉)
(Humidity) 35 to 80% RH (ensure no water condensation)
(Atmospheric pressure) 700 to 1060 hPa
When not operating:
(Temperature) -10 to 40℃ (14 to 104℉)
(Humidity) 20 to 90% RH (ensure no water condensation)
(Atmospheric pressure) 700 to 1060 hPa
In storage/transport:
(Temperature) -20 to 50℃ (-4 to 122℉)
(Humidity) 20 to 90% RH (ensure no water condensation)
(Atmospheric pressure) 700 to 1060 hPa
However, performance warranty period when storing at 50℃ is 6 months after packing.

About tested values listed above, methods to measure are followed by the standard of Konica Minolta.

※1
Dead loading does not give affection to processed image or panel. Robustness against loading of AeroDR 2 1417S is not to provide any guarantees not to be damaged, not to be broken.
※2
When a shock such as drop or hit on the floor is loaded on AeroDR 2 1417S, water resistance performance (Value as IPX6) may be lost. And the water resistance performance of AeroDR 2 1417S is not to provide any guarantees about perfect water resistance, not to be damaged, not to be broken.
※3
Specification may vary depending on system configuration or environment. The specification described above is under the condition that AeroDR SYSTEM 2 is connected to X-ray generator.
※4
The specification is based on the condition that 3 exposures within one study and interval time between studies is 5 minutes. It takes 20 seconds for positioning. Under the condition that AeroDR SYSTEM 2 has linkage with X-ray generator. When connected to CS-7 image processing workstation.
※5
The specification described above is based on full battery charge and may vary depending on system configuration or environment.