PC Software for Color Analyzer CA-S40 /
SDK for Color Analyzer CA-SDK2
Changes form Ver.1.80 to Ver. 1.80 Release2
Bug fixes
SDK for Color Analyzer CA-SDK2
- Minor problems in the Windows version were corrected.(There is no version 1.80 Release 2 for macOS.)
Changes from Ver.1.70 and Ver.1.80
Specifications
SDK for Color Analyzer CA-SDK2
- Communication timeout period during zero calibration has been extended to 60 seconds.
Bug fixes
PC software for color analyzer CA-S40
- Minor problems were corrected.
SDK for Color Analyzer CA-SDK2
- Minor problems were corrected.
Others
PC software for color analyzer CA-S40
- macOS High Sierra and macOS Mojave were excluded from the operating system environment.
- Windows 11 Pro, macOS Big Sur, and macOS Monterey were added to the operating system.
SDK for Color Analyzer CA-SDK2
- macOS High Sierra and macOS Mojave were excluded from the system requirements.
- Windows 11 Pro, macOS Big Sur, and macOS Monterey were added to the operating system list.
Changes from Ver.1.60 and Ver.1.70
Specifications
PC software for color analyzer CA-S40
- Advanced High Sensitivity Probe CA-VP427A and CA-VP410A can now be controlled.
* Advanced High Sensitivity Probe cannot be controlled via data processor CA-DP40.
SDK for Color Analyzer CA-SDK2
- Advanced High Sensitivity Probes CA-VP427A and CA-VP410A can be controlled.
* Advanced High Sensitivity Probe cannot be controlled via data processor CA-DP40. - A mode has been added to allow measurement of the Advanced High Sensitivity Probe at the same speed as the high-sensitivity probes CA-VP427 and CA-VP410.
- The color measurement range has been extended only for the Advanced High Sensitivity Probe.
Fixed problems
PC software CA-S40 for color analyzer
- Minor problems were corrected.
SDK for Color Analyzer CA-SDK2
- The baud rate set for RS-232C connection has been changed so that an error will occur if the baud rate does not match that of the CA-410 probe or the CA-DP40 data processor.
- Fixed a minor bug.
Changes from Ver. 1.50 to Ver. 1.60
PC Software for Color Analyzer CA-S40
Product specifications:
- The upper limit of Weighting Factor which can be set for Frequency Characteristics (filter) has been expanded.
- The upper limit of Sampling Number for Waveform measurement has been expanded.
Note: The firmware of the CA-410 Probe must be 1.40 or later to use the expanded Sampling Number upper limit for Waveform measurement.
System requirements:
- macOS® 10.12 (Sierra) has been removed from the list of compatible OS.
- macOS® 10.15 (Catalina) has been added to the list of compatible OS.
Bug fixes:
- Various minor bugs have been fixed.
SDK for Color Analyzer CA-SDK2
Product specifications:
- The upper limit of Sampling Number for JEITA flicker measurement has been expanded.
- The upper limit of Sampling Number for Waveform measurement has been expanded.
Note: The firmware of the CA-410 Probe must be 1.40 or later to use the expanded Sampling Number upper limit for these functions.
System requirements:
- macOS® 10.12 (Sierra) has been removed from the list of compatible OS.
- macOS® 10.15 (Catalina) has been added to the list of compatible OS.
Bug fixes:
- Various minor bugs have been fixed.
Changes from Ver. 1.40r2 to Ver. 1.50
PC Software for Color Analyzer CA-S40
Product specifications:
- A function to automatically detect the frequency of the measurement subject in the range of 10 to 240Hz has been added.
- A function to enable the shortest integration time (Single-Frame) for synchronized measurement to be selected has been added.
- A function to display VESA flicker has been added.
- A function to display u'v' chromaticity diagram (CIE 1976 UCS chromaticity diagram) has been added.
- A function to enable user calibration standard values to be imported from a file has been added.
- The user settable upper limit value for JEITA/VESA flicker measurements has been increased.
NOTE: The firmware of the CA-410 Probe must be 1.30 or later to use the newly added functions. Click here to download the firmware upgrade.
System requirements:
- Windows® 7 Professional 32-bit, 64-bit have been removed from the list of compatible OS.
- macOS® 10.13 (High Sierra) and macOS® 10.14 (Mojave) have been added to the list of compatible OS.
Bug fixes:
The following bugs have been fixed:
- Problem in which several lines could not be received when performing communication using Command communication.
- The abbreviated name for Probe CA-MP410 has been corrected to an appropriate name (Ø10miniN)
- Various other minor bugs
SDK for Color Analyzer CA-SDK2
Product specifications:
- A function to automatically detect the frequency of the measurement subject in the range of 10 to 240Hz has been added.
- A function to automatically detect the frequency of the measurement subject in the range of ±2Hz from the frequency value (in the range of 10 to 240Hz) set by the user has been added.
- A function to enable the shortest integration time (Single-Frame) for synchronized measurement to be selected has been added.
- The user settable upper limit value for JEITA/VESA flicker measurements has been increased.
NOTE: The firmware of the CA-410 Probe must be 1.30 or later to use the newly added functions. Click here to download the firmware upgrade.
System requirements:
- Windows® 7 Professional 32-bit, 64-bit have been removed from the list of compatible OS.
- macOS® 10.13 (High Sierra) and macOS® 10.14 (Mojave) have been added to the list of compatible OS.
Bug fixes:
The following bugs have been fixed:
- When using the C# wrapper (CASDKNet.dll), the upper limit which can be set by the user for the number of data used for frequency characteristics when performing flicker measurements was not the correct value.
- Various other minor bugs
Changes from Ver. 1.40 to Ver. 1.40r2
SDK for Color Analyzer CA-SDK2
Bug fixes:
The following bug has been fixed.
- A bug in the COM wrapper for CA-310 compatibility which resulted in being unable to control the CA-410 even if COM_Registration_Tool.exe was run and CA-SDK2 was selected.
Changes from Ver. 1.31 to Ver. 1.40
PC Software for Color Analyzer CA-S40
Product specifications:
- Compatibility with Probes CA-VP402, CA-VP404 and CA-VP410T has been added.
SDK for Color Analyzer CA-SDK2
Product specifications:
- Compatibility with Probes CA-VP402, CA-VP404 and CA-VP410T has been added.
- API for obtaining dominant wavelength and excitation purity using a changed white point has been added.
Changes from Ver. 1.30 to Ver. 1.31
PC Software for Color Analyzer CA-S40
Product specifications:
- Compatibility with Ø10 Probe (CIE 170-2:2015 model) CA-P410C and Ø27 Probe (CIE 170-2:2015 model) CA-P427C has been added.
Bug fixes:
The following bugs have been fixed:
- Various minor bugs.
SDK for Color Analyzer CA-SDK2
Product specifications:
- Compatibility with Ø10 Probe (CIE 170-2:2015 model) CA-P410C and Ø27 Probe (CIE 170-2:2015 model) CA-P427C has been added.
Bug fixes:
The following bugs have been fixed:
- Various minor bugs.
Changes from Ver. 1.21 to Ver. 1.30
PC Software for Color Analyzer CA-S40
Product specifications:
- Waveform measurement function has been added.
- High-frequency flicker measurement function has been added.
- Sync Assist function to support input of the measurement subject's vertical synchronization frequency when taking measurements in INT measurement sync mode has been added.
NOTE: The firmware of the CA-410 Probe must be ver. 1.10 or later to use the newly added functions. Click here to download the firmware upgrade.
Bug fixes:
The following bugs have been fixed:
- Influence of aliasing noise when performing JEITA flicker measurements has been reduced.
- Problem in which the tone values in the csv file saved when performing gamma measurements were displayed incorrectly.
- Problem in which the language of the instruction manual opened using the Help function was incorrect in some cases for the macOS edition.
- Various other minor bugs.
SDK for Color Analyzer CA-SDK2
Product specifications:
- Waveform measurement function has been added.
- High-frequency flicker measurement function has been added.
- API for controlling multiple CA-410 Probes or Data Processor CA-DP40 units has been added.
- Compatibility of the Windows COM IF wrapper has been improved.
NOTE: The firmware of the CA-410 Probe must be ver. 1.10 or later to use the newly added functions. Click here to download the firmware upgrade.
Bug fixes:
The following bugs have been fixed:
- Influence of aliasing noise when performing JEITA flicker measurements has been reduced.
- Problem in which control of multiple Data Processor CA-DP40 units could not be performed when using Bluetooth® with the macOS edition
Other:
- Variable names including chromaticity coordinates x, y in the measurement values, color-difference, values, etc. in the definitions in the header file have been changed to "sx", "sy" respectively.
Changes from Ver. 1.20 to Ver. 1.21
SDK for Color Analyzer CA-SDK2
Bug fixes:
The following bugs have been fixed:
- Problem in which when multiple probes were connected to the Data Processor CA-DP40, the measurement data from the 7th and higher probes were read incorrectly.
- Problem in which switching between the CA-SDK for CA-310 and the COM IF wrapper for CA-410 using COM_Registration_Tool.exe could not be performed correctly. See note below.
- Other minor bugs
Note: If you had previously used PC Software for Color Analyzer CA-SDK Ver. 4.50 with SDK for Color Analyzer CA-SDK2 Ver. 1.20, please perform the following after SDK for Color Analyzer CA-SDK2 Ver. 1.21 has been installed:
- Uninstall PC Software for Color Analyzer CA-SDK Ver. 4.50. At this time, if an error message appears, ignore the message and continue with the uninstallation.
- Reinstall PC Software for Color Analyzer CA-SDK Ver. 4.50.
Changes from Ver. 1.10 to Ver. 1.20
PC Software for Color Analyzer CA-S40
Product specifications:
- Control of the Data Processor CA-DP40 using the macOS edition is now possible.
Bug fixes:
- Various minor bugs have been fixed.
SDK for Color Analyzer CA-SDK2
Product specifications:
- Control of the Data Processor CA-DP40 using the macOS edition is now possible.
- A COM IF wrapper and a .NET application development wrapper have been added to the Windows edition.
Bug fixes:
- Various minor bugs have been fixed.
Changes from Ver. 1.00 to Ver. 1.10
PC Software for Color Analyzer CA-S40
Product specifications:
- macOS compatibility has been added. However, when using the macOS edition, control of only CA-410 probes is possible and control of Data Processor CA-DP40 is not possible.
- When using the Windows edition, control of the Data Processor CA-DP40 is now possible.
Bug fixes:
- Various minor bugs have been fixed.
SDK for Color Analyzer CA-SDK2
Product specifications:
- macOS compatibility has been added. However, when using the macOS edition, control of only CA-410 probes is possible and control of Data Processor CA-DP40 is not possible.
- When using the Windows edition, control of the Data Processor CA-DP40 is now possible.
- A function to enable/disable output of negative measurement values has been added.
Bug fixes:
- Various minor bugs have been fixed.